Figure 3.

Figure 3

Monosodium urate (MSU) crystals acquired from patients with gout were compared with synthetic MSU crystals. (a) Three-dimensional (3D) holotomographic image of MSU crystals embedded in the patient cells. The color bar indicates the 3D rendered RI distribution range (n = 1.340–1.440). Each square shows the x–y, y–z, or x–z plane. n: refractive index. Additionally, see Supplementary Movie S3. (b) Extensive monitoring of MSU crystals from a synovial fluid sample through stitch mode of holotomographic imaging (300 µm × 300 µm). The boxed region is enlarged in the lower panel. (c) Comparison of patient crystals with commercial MSU crystals (n = 96). Data are represented as the mean ± SD values. ***P < 0.001.