Table 1.
Published Swedish planning technique data; where no data are presented, the article does not state the data
Volume | Borghede (1997) [1] |
Borghede (1997) [6] |
Åström (2005) [2] |
Kälkner (2007) [3] |
Lennernäs (2015) [7] |
Åström (2018) [4] |
---|---|---|---|---|---|---|
Target | Dmin = 10 Gy | Dmin = 10 Gy 15 Gy to the tumor |
CTV covered with 10 Gy isodose | 10 Gy to PTV | Dmin = 10 Gy |
PTV encompassed by the 10 Gy isodose |
Margin | 2 mm | 2 mm | 2 mm | 3 mm | 3 mm | 2 mm |
Number of catheters | 6-15 | – | 6-21 | 10-18 | – | 10-22 |
Urethra | 8-9 Gy | < 8 Gy | – | – | – | 1995-1999: None 2000-2008: < 12 Gy |
Rectum | < 6 Gy | – | – | < 6 Gy | < 6 Gy | 1995-1999: None 2000-2005: < 6.5 Gy 2006-2008: < 5 Gy |
Data collected | – | 1988-1994 | 1988-2000 | 1998-1999 | 1996-2001 | 1995-2008 |