Skip to main content
. 2021 Feb 18;13(1):59–71. doi: 10.5114/jcb.2021.103588

Table 4.

Planning aims and dose constraints for the six clinics, the clinics are denoted as letters from A to F. Clinic B changed methods during the audit and provided two answers: B1, the old method and B2, the new method

Volume A B1 B2 C D E F
PTV D100% = 10 Gy Dmin = 10 Gy Dmin = 10 Gy V100% > 95% V100% > 95% V100% > 95%
V150% < 55% V120% < 70-75%
V150% < 30-35%
D90% > 9.5 Gy
CTV D90% > 100% V100% > 97%
D100% > 90%
Urethra Dmax < 12 Gy Dmax < 10 Gy Dmean ≤ 11 Gy Dmax < 120% Dmax < 11 Gy Dmax < 12 Gy Dmax < 110%
Dmax < 11.5 Gy D0.1cc < 11.4 Gy
Rectum D2cc < 7.5 Gy Dmax < 6 Gy Dmax < 6 Gy Dmax < 80% Dmax < 7 Gy Dmax < 8 Gy D10% < 65%
D2cc < 60% D2cc < 5.5 Gy
Bladder Dmax < 7.5 Gy
D2cc < 5 Gy