Detection rates of the artery of Adamkiewicz

Method (Reference) Detection Rate, % (n/N) Confirmation Rate, % (n/N) Detectors Row Phase Scan Duration Injection Rate
Seconds mL/s
IVCTA (19) 90 (63/70) 32 (20/63) 4 1 40 3.5
IVCTA (20) 90 (9/10) 89 (8/9) 8 1 40 4.0–4.5
IVCTA (18) 83 (25/30) 72 (18/25) 16 1 NA 3.5
IACTA (24) 100 (39/39) 90 (35/39) 4 or 6 1 NA 4.0–7.0
IVCTA (present study) 60 (9/15) 56 (5/9) 16 2 25 5.0
IACTA (present study) 94 (16/17) 88 (14/16) 16 2 25 5.0

Note:—IVCTA indicates intravenous CT angiography; IACTA, intra-arterial CT angiography; NA, not assessed.