Table 4.

Differences in Radiation Exposure Among Different TLIF Methods.

Total (n = 165) IGN (n = 12) Robotic (n = 62) Open (n = 56) MIS (n = 35) P
Total-procedure radiation, mGy 51.19 ± 42.02 50.21 ± 22.84 59.84 ± 32.48 22.56 ± 22.62 82.02 ± 56.24 <.001
Total-procedure radiation per level, mGy 45.52 ± 40.97 41.88 ± 27.70 51.18 ± 32.05 18.56 ± 19.53 79.41 ± 54.25 <.001
Intraoperative radiation, mGy 42.16 ± 41.81 44.69 ± 13.08 44.85 ± 34.61 14.81 ± 15.54 80.28 ± 55.6 <.001
Preoperative CT, % 47.27 25.00 82.26 37.50 8.57 <.001
Preoperative CT radiation, mGy 19.88 ± 9.48 22.09 ± 19.67 19.36 ± 7.32 20.67 ± 12.28 20.28 ± 12.16 .931

Abbreviations: TLIF, transforaminal lateral interbody fusion; IGN, intraoperative computed tomography image-guided navigation; robotic, robotic assistance; MIS, minimally invasive surgery with fluoroscopy.