Skip to main content
. 2021 Apr 13;33(3):506–515. doi: 10.1177/10406387211005433

Table 2.

Limits of detection (LOD), limits of quantification (LOQ), upper limits of quantification (ULOQ), percent recovery, matrix effect ratio, type of regression used for the calibration curve, and representative regression equations of targeted compounds.

Compound LOD (ng/mL) LOQ (ng/mL) ULOQ (ng/mL) % Recovery Matrix effect ratio Calibration curve regression utilized Representative regression equation
α-TP 0.008 0.025 10,000 44 0.42 Linear 0.0038x + 0.0084
γ-TP 0.333 1.11 1,000 41 0.22 Linear 1.37e−4x + 2.87e−5
α-TT 0.029 0.095 1,000 44 0.36 Linear 0.0047x + 4.4e−5
γ-TT 0.125 0.417 1,000 42 0.35 Linear 0.002x − 4.21e−4
α-CMBHC 0.010 0.032 1,000 66 0.42 Quadratic −2.1e−5x2 + 0.069x + 0.270
α-CEHC 0.022 0.074 1,000 93 0.54 Quadratic −1.2e−5x2 + 0.054x + 0.130
γ-CEHC 0.026 0.087 1,000 96 0.53 Quadratic −3.9e−6x2 + 0.016x + 0.056