Skip to main content
. 2021 Apr 8;8(3):1850–1860. doi: 10.1002/ehf2.13304

Table 3.

Diagnostic performance of circulating biomarkers and plasma levels of miR‐155 and miR‐206 in iCMP

Circulating biomarker Youden index AUC Sensitivity Specificity PPV NPV Accuracy
CRP 6.30 mg/L 0.62 (0.46–0.77) 72% 38% 0.66 0.44 0.59
ESR 18.50 mm 0.58 (0.44–0.72) 73% 40% 0.56 0.57 0.56
CK‐MB 22.5 U/L 0.51 (0.34–0.67) 72% 38% 0.54 0.57 0.55
Myoglobin 251 μg/L 0.39 (0.23–0.54) 69% 24% 0.36 0.55 0.41
Troponin T 34.50 ng/L 0.51 (0.36–0.65) 73% 38% 0.55 0.57 0.43
NT‐proBNP 1076 g/mL 0.51 (0.34–0.68) 73% 29% 0.49 0.55 0.51
Lake Louis criteria 0.62 (0.47–0.77) 62% 63% 0.81 0.38 0.60
miR‐21 8.1 0.56 (0.43–0.69) 68% 31% 0.71 0.39 0.57
miR‐126 39.6 0.48 (0.34–0.61) 68% 35% 0.62 0.33 0.57
miR‐133a 2.8 0.57 (0.45–0.71) 68% 35% 0.63 0.35 0.58
miR‐146b 4.6 0.61 (0.49–0.73) 68% 38% 0.61 0.37 0.59
miR‐155 0.87 0.68 (0.55–0.80) 75% 42% 0.65 0.53 0.61
miR‐206 2.27 0.67 (0.55–0.79) 77% 48% 0.70 0.57 0.66

CK‐MB, creatine kinase myocardial band; CRP, C‐reactive protein; ESR, erythrocyte sedimentation rate; NT‐proBNP, N‐terminal pro‐brain natriuretic peptide.

Receiver operating characteristic curve analysis was applied. Area under the curve (AUC), sensitivity, specificity, positive predictive value (PPV), negative predicative value (NPV), and diagnostic accuracy for diagnostic confirmation of inflammatory cardiomyopathy (iCMP) were calculated.