Skip to main content
. 2021 May 14;11:10320. doi: 10.1038/s41598-021-88264-x

Table 4.

Experimental design and results of central composite design (CCD).

Run order Concentration Temperature Carbon Inoculum Response
Experimental Predicted
1 100 35 1.5 50005000 71.1 71.2
2 100 45 1.5 50005000 30.2 38.1
3 75 30 3 100000000 80.1 73.6
4 125 40 3 10000 22.4 18.6
5 50 35 1.5 50005000 91.2 87.6
6 75 30 3 10000 22.3 30.6
7 125 40 0 10000 15.4 14.5
8 100 35 − 1.5 50005000 11.2 17.3
9 125 40 0 100000000 35.4 28.5
10 100 35 1.5 50005000 71.5 71.2
11 75 40 0 10000 37.7 43.6
12 100 35 1.5 50005000 71.9 71.2
13 125 30 3 10000 11.1 12.0
14 125 30 3 100000000 65.7 55.5
15 125 40 3 100000000 69.2 57.1
16 100 35 1.5 50005000 69.8 71.2
17 75 40 0 100000000 65.1 57.1
18 125 30 0 100000000 33.4 23.8
19 100 35 1.5 50005000 71.6 71.2
20 75 40 3 100000000 90.2 74.3
21 100 25 1.5 50005000 25.4 27.8
22 100 35 1.5 − 49985000 6.2 3.4
23 75 40 3 10000 34.1 36.3
24 150 35 1.5 50005000 30.1 40.3
25 100 35 1.5 149995000 45.2 56.9
26 125 30 0 10000 3.4 4.8
27 100 35 1.5 50005000 71.5 71.2
28 75 30 0 100000000 60.2 53.5
29 75 30 0 10000 30.2 35.0
30 100 35 4.5 50005000 30.4 41.6
31 100 35 1.5 50005000 71.3 71.2