Skip to main content
. 2021 Apr 22;22(9):4401. doi: 10.3390/ijms22094401

Table 1.

Detailed histological measurements (infarction size, heart volume) and echocardiographic parameters (EF, FS, End-Diastolic Diameter, Heart rate, Cardiac output).

Parameter Control
n = 6
PS
n = 6
PS after
n = 6
p
Infarct size
(% from 3D reconstructed volume)
12.15 ± 2.57 8.33 ± 2.56 $ 7.95 ± 3.03 $ * p = 0.0337
Heart Volume (µm3) 14.674 ± 2869 15.140 ± 1538 16.401 ± 2074 p = 0.4037
Ejection Fraction—EF (%) 29.17 ± 4.44 38.50 ± 7.53 $ 38.17 ± 5.07 $ * p = 0.0225
Fractional shortening—FS (%) 19.28 ± 1.33 23.94 ± 1.13 $ 23.05 ± 1.07 * p = 0.0324
Cardiac output (ml/min) 10.34 ± 2.68 18.22 ± 3.94 $ 18.65 ± 4.63 $ * p = 0.0028
End-Diastolic Diameter (mm) 4.16 ± 0.22 3.83 ± 0.19 $ 3.97 ± 0.21 * p = 0.0500
Heart rate (bpm) 384 ± 27.72 381 ± 33.83 373 ± 36.36 p = 0.8559

Values ± SD, $ significant difference vs Control, Phosphatidylserine (PS); Ejection Fraction (EF); Fractional shortening (FS), * significant difference.