Table 2.

Ventilation rates according to window opening ratio.

Case Ventilation strategy
Measurement results
Outdoor conditions
Cross- or Single-sided ventilation Opening ratio Ventilation rate [ACHb], indoor air velocity [m/s] South side
East side
Wind velocity [m/s] Wind direction [°] Temp. difference [°C]
Mean SD Na Mean SD Na
Base case 0% ACH 0.30 0.00 2 0.32 1 0.41 0 6.20
Case 1–1 Cross-ventilation 15% ACH,
m/s
6.38
0.08
1.85
0.03
11
6.70
0.10
2.57
0.02
7
0.70 292.5
2.79
Case 1–2 30% ACH,
m/s
10.53
0.12
2.61
0.03
18
12.92
0.19
5.81
0.04
7
1.05 0
3.87
Case 1–3 100% ACH,
m/s
22.39
0.24
3.98
0.07
5
22.60
0.19

1
1.06 0
3.28
Case 2–1 Single-sided ventilation 15% ACH,
m/s
2.13
0.05
0.23
0.01
2
2.81
0.06
0.86
0.01
3
0.84 292.5
3.01
Case 2–2 30% ACH,
m/s
2.90
0.05
0.74
0.02
4
3.65
0.07
1.20
0.02
4
1.12 0
3.96

Bold emphasizes ACH - the most important value in this table.

a

N: number of measurements.

b

ACH: air changes per hour.