Measured sheet resistance, average sheet resistance, and the nonuniformity factor (NUF) of AgNW transparent electrode at different concentrations and spin speeds.

Concentration
mg/mL
Spin Speed
rpm
Measured Sheet Resistance (1)
Ω/sq
Measured Sheet Resistance (2)
Ω/sq
Measured Sheet Resistance (3)
Ω/sq
Average Sheet Resistance
Ω/sq
NUF
1 mg/mL 1000 104.25 117.52 181.55 134.44 0.251
2000 264.69 140.85 269.77 225.10 0.265
3000 523.48 436.7 114.16 358.11 0.492
2 mg/mL 1000 37.01 34.34 35.93 35.76 0.031
2000 39.26 39.46 39.11 39.28 0.004
3000 46.58 55.4 56.04 52.67 0.082
3 mg/mL 1000 17.82 22.2 20.26 20.09 0.089
2000 28.37 26.62 28.39 27.79 0.030
3000 40.78 31.98 30.6 34.45 0.131