Skip to main content
. 2021 Feb 3;62(3):502–510. doi: 10.1093/jrr/rraa138

Table 2.

Planning aims for HR-CTV and OARs in each brachytherapy session

Treatment schedule Dose constraint HR-CTV D90 Rectum D2cc Bladder D2cc Sigmoid D2cc
1, 2 Preferable ≥7.0 Gy <5.5 Gy <6.5 Gy <5.5 Gy
limit ≥6.0 Gy 5.5–6.0 Gy 6.5–7.6 Gy 5.5–6.0 Gy
3 Preferable ≥7.0 Gy <5.0 Gy <6.0 Gy <5.0 Gy
limit ≥6.0 Gy 5.0–5.2 Gy 6.0–6.5 Gy 5.0–5.2 Gy