Skip to main content
. 2021 Mar 19;26(1):33–41. doi: 10.1089/apb.21.926968

Table 1.

Test conditions for each trial a

Trial No. H2CO Vapor Source Targeted PF Mass Sublimated Into Chamber Air (g) Temperature RH (method) Efficacy or H2CO Characteristic
1 Paraformaldehyde 5.2 Ambient (21°C-22°C) 75% starting (saltsb) Efficacy
2 Paraformaldehyde 5.2 Ambient 70%-75% controlled (salts) Characteristic
3 Paraformaldehyde 5.2 10°C controlled 75% starting (salts) Efficacy
4 Paraformaldehyde 5.2 10°C controlled 70%-75% controlled (salts) Characteristic
5 Paraformaldehyde 5.2 Ambient 75% starting (vaporc) Characteristic (x1d)
6 Paraformaldehyde 5.2 Ambient 75% starting (vapor) Characteristic (x5e)
7 Paraformaldehyde 5.2 Ambient 75% starting (vapor) Characteristic (x20f)
8 Paraformaldehyde 1 Ambient 70% starting (vapor) Efficacy
9 Formalin 1 Ambient 70%-80% starting (vapor) Efficacy
10 Formalin 5.2 10°C controlled 75% starting (vapor) Efficacy
11 Formalin 1 10°C controlled 75% starting (vapor) Efficacy
a

g, gram or grams; PF, paraformaldehyde; RH, relative humidity.

b

salts, RH generated with saturated salt in containers.

c

vapor, RH generated with water vapor (boiled).

d

x1, surface area of test chamber during normal setup.

e

x5, test chamber surface area increased x5 versus normal setup with 20 clear Plexiglas panels.

f

x20, test chamber surface area increased x20 versus normal setup with 85 clear Plexiglas panels.