Skip to main content
. 2021 Mar 26;11(2):61–65. doi: 10.4103/2045-9912.311496

Table 2.

The oxidation-reduction potential and the hydrogen molecule concentration in electrolyzed water generated by use of electrolytic apparatus LB-002 (Lita hydrogen dual bottle) with electrolysis of tap water for 30 minutes

Oxidation-reduction potential (mV) Hydrogen molecule concentration (μg/L)
Before electrolysis (tap water) +267.0±3.3 0.3±0.4
After electrolysis
 1 –283.8±20.9 579.0±30.6
 2 –241.5±59.3 473.8±22.1
 3 –219.5±38.3 389.0±11.0
 4 –236.8±7.9 475.3±72.9
 Mean±SD (all 16 samples of 1–4) –245.4±43.9 479.3±79.1

Note: Data are expressed as the mean ± SD (n = 4). Four independent measurements were executed for each lot apparatus differently manufactured.