Skip to main content
. 2021 Mar 4;36(1):32–38. doi: 10.4103/ijnm.IJNM_112_20

Table 1.

Detailed computed tomography acquisition parameters for each protocol

Scan Scan type Thickness Pitch Tube potential (kV) Tube current (mA) Prep group (sec)
Head and neck arterial CT Helical 1.25 mm 0.938:1 120 150-180 (smart mA) 25-30 s based upon bolus tracking (arterial phase CT)
Brain CT Axial 2.5 mm - 120 250 mA 0 s
Pelvis arterial CT Helical 1.25 mm 0.938:1 120 150-200 (Smart mA) 25-30 s based upon bolus tracking (arterial phase CT)
Thorax CT Helical 1.25 mm 1.375:1 120 150-180 (smart mA) 5.9 s
Whole Body CT Helical 3.75 mm 1.375:1 120 150-320 (smart mA) 40-50 s delay based upon contrast administered (venous phase CT)

Smart mA – Modulates tube current according to patient characteristics. In Thorax CT 5.9 sec prep is to used to instruct patient to hold their breath during acquisition (to limit motion artifacts in image). For simplicity of calculation, Smart Prep CT was included in Arterial phase CT. CT: Computed tomography