Skip to main content
. 2021 May 18;11:10517. doi: 10.1038/s41598-021-89990-y

Table 1.

Summarized results from the experiment with 100 MeV 73Ge ions.

Sample Total Non-saturation Saturation
Integral Mean (chan.) RMS (chan.) Integral Mean (chan.) RMS (chan.) Integral
Forward 100 MeV 73Ge
Au 0.9997 857.9 78.4 0.9995 857.9 78.2 0.0002
ZnO large 0.9953 928.3 120.2 0.9692 920.1 110.7 0.0257
ZnO small 0.9972 945.6 103.1 0.9525 932.2 83.9 0.0444
ZnO/GaN medium 0.9996 935.1 149.0 0.8729 891.3 101.4 0.1258
ZnO/GaN small 0.9997 926.5 144.7 0.8887 888.0 100.7 0.1104
Backward 100 MeV 73Ge
Au 0.9991 971.3 128.1 0.9878 968.4 125.8 0.0104
ZnO large 0.9955 985.6 137.2 0.9079 961.4 118.3 0.0863
ZnO small 0.9939 930.8 144.8 0.9046 900.9 114.3 0.0880
ZnO/GaN medium 0.9934 945.0 186.2 0.7838 867.3 123.9 0.2072
ZnO/GaN small 0.9929 899.9 184.3 0.8238 831.0 114.3 0.1682