Table 1. 7 Tesla imaging protocol.

MPRAGE MP2RAGE T2-TSE DWI T2-TSE TOF
Orientation Coronal oblique Axial Coronal oblique Coronal oblique Axial Coronal oblique
Scan time (min:s) 7:40 8:08 6:50 9:19 (18:38 a ) 6:50 10:13
Voxel size (mm 3 ) 0.7 × 0.7 × 0.7 0.7 × 0.7 × 0.7 0.4 × 0.4 × 2.0 1.05 × 1.05 × 1.05 0.4 × 0.4 × 2.0 0.35 × 0.26 × 0.4
Slice number (slabs) 224 240 60 66 55 240(4)
FOV (mm 2 ) 225 × 169 224 × 168 200 × 168 210 × 210 200 × 168 200 × 170
2D/3D 3D 3D 2D 2D 2D 3D
TR (ms) 3,000 6,000 6,000 7,200 6,000 18.0
TE (ms) 4.1 3.62 59 67.6 59 5.58
TI (TI2; ms) 1,050 1,050 (3,000) N/A N/A
Flip angle (2nd flip angle; degree) 7 5(4) 180 180 180 20
Resolution 320 × 240 320 × 240 512 × 432 200 × 200 512 × 432 768 × 491
Directions N/A N/A N/A 64 N/A N/A

Abbreviations: 2D, two-dimensional; 3D, three-dimensional; DWI, diffusion-weighted imaging; FOV, field of view; MPRAGE, magnetization prepared rapid acquisition with gradient echo; N/A, not available; T2-TSE, T2-weighted turbo spin echo; TE, echo time; TI, inversion time; TOF, time of flight; TR, repetition time.

a

Diffusion was acquired with both anterior-posterior and posterior–anterior readout directions.