Skip to main content
. 2007 Oct;28(9):1628–1632. doi: 10.3174/ajnr.A0814

Thoracic and lumbar spine CT protocol

Series Scan Type Detector Configuration Pitch Speed FOV (cm) kVp Auto mA
Rotation Time Section Thickness Reconstruction Interval Prep Group Amount Saline Flush Rate
Min Max NI
Helical 64 × 0.625 1.375:1 68.75 18 120 150 250 12 0.8 2.5 2

Note:—Min, minimum; Max, maximum; –, not applicable.