Skip to main content
. 2007 Nov;28(10):1902–1908. doi: 10.3174/ajnr.A0697

Table 2:

Results and cases arbitrarily divided into 3 groups in terms of stent visibility with angiographic CT data reconstructions*

Case No. (Age, y) Stent (Neuroform 2/3) Maximum Aneurysm Diameter, mm No. of coils Aneurysm Occlusion Rate, I > 95% or II < 95% Stent Visibility, Grade 1, 2, or 3
1 (66) NF3, 4.5 × 20 mm 18 18 II 3
2 (63) NF3, 4.5 × 20 mm 4 2 II 1
3 (35) NF3, 4.5 × 20 mm 4.5 5 I 1
4 (61) NF3, 4.0 × 20 mm 13 4 II 3
5 (57) NF3, 4.0 × 20 mm 12 7 I 2
6 (24) NF2, 4.5 × 20 mm 10 10 I 2
7 (44) NF3, 4.0 × 20 mm 2.5 3 I 1
8 (45) NF3, 3.5 × 20 mm 10 8 I 2
9 (46) NF3, 4.0 × 20 mm 11 14 II 3
10 (58) NF3, 4.0 × 20 mm 4 (saccular compartment) 7 I 3
11(47) NF3, 4.5 × 30 mm 11 11 I 3

Note:—NF indicates Neuroform.

*

Group 1, excellent; Group 2, favorable; Group 3, poor (see column on the right).