. 2021 Apr 29;2(3):487–493. doi: 10.1093/ehjdh/ztab044

Table 2.

Details of data from home sensors and cardiac implantable electronic devices

Before LD During LD
Home sensors data (N = 51)
 Days of remote monitoring 28 ± 6 31 ± 1 <0.01
 Days of transmissions 24 ± 8 27 ± 6 0.01
 Adherence, % 84 ± 21 87 ± 19 0.08
 Weight, kg 83 ± 16 83 ± 16 0.12
 SBP, mmHg 121 ± 19 121 ± 18 0.91
 DPB, mmHg 73 ± 9 73 ± 9 0.86
 Heart rate, b.p.m. 68 ± 10 67 ± 10 0.36
Device data (N = 21)
 Activity, h/day 2 ± 1 2 ± 1 0.27
 Heart rate, b.p.m. 71 ± 5 70 ± 6 0.08
 Heart rate variability, ms 89 ± 44 78 ± 46 0.05
 AF burden, h 84 ± 146 86 ± 146 0.72
 Thoracic impedance, Ohms 66 ± 8 66 ± 9 0.61

AF burden, atrial fibrillation burden (total hours/31 days); DBP, diastolic blood pressure; LD, lockdown; SBP, systolic blood pressure.