Summary of results obtained from DLS analysis of research-grade nTiO2 (Sigma Aldrich, 19.9 ± 6.6 nm (TEM)) suspensions in NSW.

Time (h) 1 mg L−1 100 mg L−1
Z-Average size (d.nm) Polydispersity index (PDI) Z-Average size (d.nm) Polydispersity index (PDI)
0 1580 ± 124 0.804 ± 0.170 1624 ± 113 0.580 ± 0.156
1 5626 ± 586 1.000 6560 ± 464 1.000
2 2262 ± 129 0.890 ± 0.191 4994 ± 198 1.000
4 1393 ± 284 0.907 ± 0.081 1569 ± 129 0.737 ± 0.108
24 2367 ± 665 1.000 5636 ± 670 0.980 ± 0.035
48 2253 ± 519 1.000 4133 ± 956 0.957 ± 0.055
72 2741 ± 670 1.000 1966 ± 936 0.978 ± 0.025
168 Undetectable 1994 ± 141 1.000
240 Undetectable 1564 ± 168 0.953 ± 0.060
336 Undetectable 3133 ± 215 1.000