Skip to main content
. 2021 May 11;33(5):057107. doi: 10.1063/5.0050058

FIG. 11.

FIG. 11.

Streamline flow map at the middle y-z plane (left) and aerosol wall deposition on the ceiling and right-side walls (right) for case FB2. The magenta dot represents the inject location and the black dashed lines in the streamline maps are used to illustrate potential pathways of the aerosols being extracted by the HUV or air cleaner.