TABLE I.
Infector location | Air cleaner location | Aerosol distribution after a 50-min simulation | |||||
---|---|---|---|---|---|---|---|
Extracted by air cleaner | Extracted by ventilation (%) | Suspended (%) | Deposit on the wall (%) | ||||
Baseline | Case A | A | NA | NA | 5 | 15 | 80 |
Case B | B | NA | NA | 8 | 13 | 79 | |
Placement effect | Case A1 | A | 1 | 43% | 3 | 3 | 51 |
Case A2 | A | 2 | 41% | 4 | 7 | 48 | |
Case A3 | A | 3 | 19% | 6 | 9 | 66 | |
Case A4 | A | 4 | 14% | 5 | 12 | 69 | |
Case B1 | B | 1 | 24% | 2 | 10 | 64 | |
Case B2 | B | 2 | 75% | 2 | 1 | 22 | |
Case B3 | B | 3 | 27% | 6 | 7 | 60 | |
Case B4 | B | 4 | 24% | 6 | 7 | 63 | |
Case A12 | A | 1 and 2 | 53% | 1 | 2 | 44 | |
Case B12 | B | 1 and 2 | 84% | 2 | 1 | 13 | |
Flow direction | Case FA2 | A | 2a | 24% | 4 | 6 | 66 |
Case FB2 | B | 2a | 16% | 3 | 8 | 73 | |
Ventilation effect | Case VA | A | NA | NA | 5 | 12 | 83 |
Case VB | B | NA | NA | 8 | 12 | 80 | |
Room size effect | Case LB | B | NA | NA | 11 | 14 | 75 |
Case LB2 | B | 2 | 20% | 10 | 8 | 62 | |
Case LB22 | B | 2 and 2 | 35% | 5 | 8 | 52 | |
Case LB12 | B | 1 and 2 | 28% | 12 | 6 | 54 | |
Thermal effect | Case TA2 | A | 2 | 41% | 3 | 9 | 41 |
Case TB2 | B | 2 | 65% | 1 | 4 | 30 | |
Case TA2H | A | 2b | 26% | 3 | 10 | 61 | |
Case TB2H | B | 2b | 78% | 1 | 1 | 20 |
Represents the air cleaner with upward flow design.
Represents placing the air cleaner 1.3 m above the ground.