Experimental Factors and Results.

Process Parameters Responses
Trials Magnetic Field (T) Current (A) T-on (µs) T-off (µs) Flushing Type W/P MRR (mg/min) MH (HV) SR (µm)
1 0 4 30 30 1 1 28.815 209.3 0.21
2 0 4 45 45 3 2 21.320 306.6 0.19
3 0 4 90 90 2 3 19.739 353.9 0.39
4 0 10 30 45 3 3 16.012 309.0 0.21
5 0 10 45 90 2 1 24.584 289.8 0.67
6 0 10 90 30 1 2 18.542 389.0 0.79
7 0 16 30 90 2 2 36.255 225.0 0.18
8 0 16 45 30 1 3 28.400 360.9 0.39
9 0 16 90 45 3 1 31.128 262.9 0.12
10 0.33 4 30 45 2 2 23.620 202.6 0.22
11 0.33 4 45 90 1 3 15.683 241.8 0.19
12 0.33 4 90 30 3 1 28.631 245.0 0.22
13 0.33 10 30 90 1 1 30.523 134.2 0.13
14 0.33 10 45 30 3 2 20.675 290.7 0.21
15 0.33 10 90 45 2 3 29.850 302.8 0.31
16 0.33 16 30 30 3 3 29.518 316.2 0.20
17 0.33 16 45 45 2 1 43.520 262.9 0.54
18 0.33 16 90 90 1 2 41.663 202.6 0.32
19 0.66 4 30 90 3 3 31.231 241.8 0.22
20 0.66 4 45 30 2 1 53.524 245.0 0.92
21 0.66 4 90 45 1 2 30.575 234.2 0.14
22 0.66 10 30 30 2 2 49.850 290.7 1.95
23 0.66 10 45 45 1 3 39.411 302.8 0.30
24 0.66 10 90 90 3 1 53.620 216.2 0.36
25 0.66 16 30 45 1 1 51.653 202.9 1.31
26 0.66 16 45 90 3 2 38.661 262.6 0.55
27 0.66 16 90 30 2 3 29.573 341.8 0.80