Skip to main content
. 2021 May 25;789:147976. doi: 10.1016/j.scitotenv.2021.147976

Table 1.

The descriptions of particulate matter sampling methods from 13 sites in 10 cities in Turkey.

Cities Site PM Sampling Equipment Sampling period Number of samples PM Fraction Filter Types Sampling volume,
m3 day−1
İstanbul HG SKC Filter Pack Sampler 13.05.2020–04.06.2020 20 TSP and PM2.5 PTFE 7.2
Tekirdağ HG Dichotomous PM Sampler 17.05.2020–31.05.2020 20 PM2.510 and PM2.5 PTFE 24
Bursa HG High Volume Air Sampler 21.05.2020–27.05.2020 7 TSP GF 278
Zonguldak HG Dichotomous PM Sampler 16.05.2020–28.05.2020 26 PM2.510 and PM2.5 PTFE 24
Konya HG High Volume Air Sampler 21.05.2020–03.06.2020 14 TSP GF 360
Ankara U Low Vol Stack Filter Unit 30.05.2020–14.06.2020 10 TSP PTFE 24
Bolu U SKC Filter Pack Sampler 14.05.2020–22.05.2020 9 TSP PTFE 7.2
İzmir U Zambelli PM Sampler 14.05.2020–02.06.2020 9 PM10 PTFE 24
İstanbul U High Vol Cascade Impactor 13.05.2020–02.06.2020 48 0.49–7.2 μm (6 fractions) GF 1422
Eskişehir U SKC Filter Pack Sampler 16.05.2020–30.05.2020 14 TSP PTFE 7.2
Bursa UB High Volume Air Sampler 21.05.2020–27.05.2020 7 TSP GF 318
Bolu UB SKC Filter Pack Sampler 14.05.2020–22.05.2020 9 TSP PTFE 7.2
Antalya UB Low Vol Stack Filter Unit 18.05.2020–03.06.2020 10 PM10 NPF 24

U: Urban site, UB: Urban background, HG: Hospital garden, GF: Glass fiber filter, PTFE: Teflon filter, NPF: Nucleopore Polycarbonate filter, TSP: Total Suspended Particulate, PM2.510: Particulate Matter between 2.5 and 10 μm, PM10: Particulate Matter ≤10 μm.