Skip to main content
. Author manuscript; available in PMC: 2021 May 25.
Published in final edited form as: J Occup Environ Hyg. 2017 Nov;14(11):839–852. doi: 10.1080/15459624.2017.1335404

Table 5.

Results from statistical analysis for comparison of control performance of downflow booths

PRR
Measurement instrument Experimental factors Levels Sample size Geometric mean Geometric standard deviation

DustTrak Booth size* Short 40 161.58 1.115
Regular 78 117.77 2.073
Extended 76 140.92 1.501

Supply air velocity*, m/s (fpm) 0.41 (80) 95 112.66 1.921
0.51 (100) 99 160.27 1.389

Location for powder transfer Near 117 139.93 1.739
Far 77 127.52 1.685

Use of curtains* Yes 97 119.96 1.755
No 97 151.61 1.642

OPS Booth size* Short 40 159.66 1.109
Regular 76 124.11 1.90
Extended 79 150.00 1.387

Supply air velocity*, m/s (fpm) 0.41 (80) 95 125.41 1.653
0.51 (100) 100 157.86 1.481

Location for powder transfer* Near 118 152.65 1.347
Far 77 125.11 1.863

Use of curtains* Yes 97 130.23 1.733
No 98 152.79 1.408

Note: Experimental factors showing statistically significant difference were marked with asterisks.