Skip to main content
. 2021 May 25;14(5):5665–5688. doi: 10.1007/s12652-021-03282-x

Table 13.

Comparison between macro average precision, sensitivity, f-measure and specificity for different models applied on MosMed dataset

Models Macro average
Prec (%) Sens (%) F-measure (%) Spec (%)
Spatial articulated feature (HOG + DAISY) fusion + SVM 73.45 84.41 72.92 95.82
Inception-v3 87.18 85.80 86.45 95.89
Mobilenet-v2 93.17 88.88 90.90 96.48
ResNet-50 92.80 89.02 90.80 96.54
Xception 94.42 91.30 92.78 97.30
The proposed modified Norm-VGG16 97.46 94.22 95.77 98.42
The proposed COV-CAF model 97.58 96.73 97.14 98.97