Skip to main content
. 2003 Jun;24(6):1067–1074.

TABLE 1:

Aneurysm detection at rotational DA and MIP, SSD, and volume-rendering 3D DA

Aneurysm Detection Score* Rotational DA (n = 30) MIP 3D DA (n = 30) SSD 3D DA (n = 30) Volume-Rendering 3D DA (n = 30)
+2 24 (80) 25 (83) 27 (90) 29 (97)
+1 4 (13) 3 (10) 3 (10) 1 (3)
0 2 (7) 2 (7) 0 (0) 0 (0)
−1 0 (0) 0 (0) 0 (0) 0 (0)
Mean score ± SD 1.73 ± 0.58 1.77 ± 0.57 1.90 ± 0.31 1.97 ± 0.18

Note.—Data are number of aneurysms. Numbers in parentheses are percentages.

*

+2 indicates sufficient visualization; +1, ambiguous visualization; 0, poor visualization; −1, misinterpretation.