Table 1.
Summary statistics of motion censoring
| % Invalid scans | FD before censoring (mm) | FD after censoring (mm) | |||||
|---|---|---|---|---|---|---|---|
| ART | Power | Jenkinson | ART | Power | Jenkinson | ||
| TYP | 16 (24) | 0.41 (0.59) | 0.45 (0.54) | 0.24 (0.31) | 0.15 (0.07) | 0.19 (0.09) | 0.09 (0.04) |
| DD | 14 (16) | 0.28 (0.21) | 0.32 (0.23) | 0.17 (0.13) | 0.14 (0.04) | 0.17 (0.04) | 0.08 (0.02) |
| DCD | 26 (23) | 0.60 (0.67) | 0.65 (0.68) | 0.34 (0.35) | 0.17 (0.04) | 0.21 (0.06) | 0.11 (0.03) |
| COM | 18 (18) | 0.30 (0.25) | 0.34 (0.28) | 0.18 (0.15) | 0.15 (0.04) | 0.18 (0.06) | 0.09 (0.05) |
ART’s FD measure has been used to censor invalid scans. Power (Power et al. 2012) and Jenkinson (Jenkinson et al. 2002) FDs are also provided for comparison purposes. Values are mean (SD).