Skip to main content
. 2021 May 13;11(5):410. doi: 10.3390/jpm11050410

Table 1.

Dosimetry of dose distribution for accelerated partial breast irradiation, taking into account the parameters of mean dose, Dmax, V5, and V20 in OAR (heart and lungs).

First Author Year Number of Patients Target Total Dose [Gy] Delivery Technique OAR Mean Dose Dmax V5 V20
Taghian [26] 2006 25 APBI 32 3DCPT Heart 0 - 0.00% 0.00%
Lungs - - 3.00% 1.00%
Kozak [27] 2006 24 APBI 32 3DCPT Heart 0.1 - 0.00% 0.00%
Left Lung 0.5 - 3.00% 1.00%
Toscas [28] 2010 14 APBI, deep-seated tumors 16 IMPT Heart 0.01 - 0.00% -
Left Lung 0.2 - V3:1.80% V10:0.20%
Right Lung 0.01 - V3:0.00% -
Wang [29] 2013 11 APBI 38.5 PSPB Heart - 3.2 - -
Lungs 0.61 - 3.50% 0.10%
Galland-Girodet [30] 2014 19 APBI 32 PSPB Heart 0 3.8 0.40% 0%
Lungs 0.5 20.4 3.10% 0.70%
Hansen [31] 2015 12 APBI, breast cancer treated with SAVI 34 PSPB Heart 0.0 0.43% - -
Left Lung 0.04 34.41% - -

OAR—organ at risk; Dmax—maximum dose; V5—the volume of organ receiving 5 Gy; V20—the volume of organ receiving 20 Gy; APBI—accelerated partial breast irradiation; 3DCPT—three-dimensional conformal proton therapy; IMPT—intensity modulated proton therapy; PSPB—passive scattering proton beam; SAVI—Strut-Adjusted Volume Implant.