Table 3.
Ten-fold mean (standard deviation) of the prediction model’s performance when applied to image samples from exclusively male or exclusively female total hip arthroplasty patients. Samples had a dislocation frequency of 2% and included no images from the training subset.
Index | Male Patients | Female Patients | P-value |
---|---|---|---|
Sensitivity | 84.9 (7.0) | 90.0 (3.9) | 0.044 |
Specificity | 61.8 (5.2) | 43.6 (5.6) | 0.001 |
Positive Predictive Value | 4.30 (0.4) | 2.95 (0.4) | 0.001 |
Negative Predictive Value | 99.5 (0.2) | 99.6 (0.2) | 0.346 |
Accuracy | 62.3 (5.0) | 44.8 (5.5) | 0.001 |