Skip to main content
. 2020 Sep 24;197(6):474–486. doi: 10.1007/s00066-020-01685-x

Table 2.

EQD2 for CyberKnife® deposed to subvolumes of the critical organs at risk (OAR) (rectum, sigmoid, bladder)

Subvolume/Organ Dose to subvolume (Gy)
EQD2 (Gy) to OARs (CyberKnife)
Rectal wall
D 0.1cc 26.9 ± 4
D 2.0cc 13.8 ± 2.6
D 5.0cc 6.2 ± 2.2
Sigmoid wall
D 0.1cc 22.8 ± 5
D 2.0cc 11.4 ± 3.6
D 5.0cc 6.2 ± 1.9
Bladder wall
D 0.1cc 36.2 ± 5.5
D 2.0cc 25.7 ± 4.3
D 5.0cc 15.4 ± 2.4