Skip to main content
. 2021 May 26;6:20. doi: 10.1186/s41181-021-00133-0

Table 2.

Outline of the [18F]DPA-714 cassette on the Trasis AllinOne radiosynthesiser, with description of reagent and materials position. Positions outlined in boldface are original parts of the commercially available [18F]FDOPA cassette

Manifold position Reagents or materials attached
1 vertical PE tubing to [18O]H2O recovery vial
1 horizontal Silicone tubing to pressure inlet
2 Spike, white Luer Lock ring and barrel for 20 mm vial
3 3 mL sterile syringe with Luer Lock
4 Silicone tubing connected to QMA cartidge in position 5
5 Activated QMA cartridge
6 3 mL sterile syringe with Luer Lock (activity inlet)
7 Reactor 6 mL with 2 tubes (male connector to cassette, female to exhaust)
8 Spike, red Luer Lock ring with barrel for 20 mm vial
9 10 mL BD PlastiPak sterile syringe with Luer Lock
10 Spike, blue Luer Lock ring
11 PE tubing OD 2 mm length 150 mm, connected to Load port of HPLC unit
12 Spike, green Luer Lock ring with barrel for 20 mm vial
13 PE tubing OD 2 mm length 150 mm, connected to 25 mL HPLC product receiving vial via sterile needle
14 20 mL HSW Norm-Ject sterile syringe with Luer Lock
15 PE tubing OD 2 mm length 100 mm, connected to Sep-Pak C18 Plus cartridge in position 17
16 0.9% NaCl for injection bottle, connected to valve using PE tubing OD 2 mm length 150 mm with spike
17 Activated Sep-Pak C18 Plus cartridge
18 vertical Tubing to dispensing hot cell
18 horizontal Silicone tubing to exhaust
Other components Reagents or materials attached
Collect port HPLC unit PE tubing OD 2 mm length 150 mm, connected to 25 mL HPLC product receiving vial via sterile needle
HPLC product collection 25 mL vial Connected to cassette via tubing in Load port and postion 13
QMA reagent for elution (10 mL vial) Connected to position 2 via spike
Precursor solution (10 mL vial) Connected to position 8 via spike
Quench solution (25 mL vial) Connected to position 10 via spike
Ethanol solution (10 mL vial) Connected to position 12 via spike
0.9% NaCl for injection solution (250 mL bottle) Connected to position 16 via tubing and spike