Skip to main content
. 2021 Apr 7;6(4):1461–1481. doi: 10.1021/acssensors.1c00183

Table 10. COPs and COF Used as Anion Sensors.

material anion analyte sensing mechanism LOD KSV (M–1) ref
TT-COF CrO42– ACQ 0.343 mM 1.4 × 104 (123)
TT-COF Cr2O72– ACQ 0.343 mM 1.4 × 104 (123)
TT-COF MnO4 ACQ 0.320 mM 1.5 × 104 (123)
DATGCl F PET (quenching) 5 ppb 2.25 × 103 (124)