Skip to main content
. 2021 Apr 7;6(4):1461–1481. doi: 10.1021/acssensors.1c00183

Table 2. COPs Used as Nitro Explosive Sensors.

material explosive sensing mechanism KSV (M–1) LOD ref
MAEC-PMA TNP static quenching 2.95 × 104 93.3 nM (59)
CMP-LS1 TNP PET, RET 5.05 × 104 n/a (54)
CMP-LS2 TNP PET, RET 3.70 × 104 n/a (54)
COP-612 TNP static quenching 2.5 × 105 n/a (52)
COP-401 TNP PET (dynamic quenching) 8.3 × 104 <1 ppm (53)
COP-301 TNP PET (dynamic quenching) 2.6 × 105 <1 ppm (53)
SNW-1 TNP quenching 9.4 × 104 50 nM (58)
A-NS TNP static quenching 8 × 105 90 nM (56)
PrTAPB-Azo-COP TNP static quenching 1.1 × 104 n/a (57)
COP-3 TNP PET (static quenching) 1.45 × 104 <1 ppm (60)
DTF TNP quenching 2.08 × 103 0.722 μM (51)
LMOP-15 TNP PET (quenching) 2.6 × 104 0.33 μM (61)
LPCMP2 TNT PET 4.15 × 103 3.64 μM (55)
PCPDI o-NP ACQ, IFE 1.74 × 105 17.2 pM (49)
DP2A2 o-NP PET (static quenching) 2.00 × 104 1.5 nM (50)