Skip to main content
. 2021 May 17;21(10):3487. doi: 10.3390/s21103487

Table 1.

Sensitivity coefficients: ratio between each sensor output (positive in compression) and nominal load (positive in traction) for the six tested load conditions.

Sensor ID Orientation X Y Z XY YZ XZ
p 1 X −1.518 0.032 0.142 0.870 0.044 −0.529
p 2 Y 0.212 −1.629 0.206 0.599 −0.236 0.117
p 3 Z 0.343 0.284 −1.772 0.036 1.109 0.971
p 4 X′ −0.891 −0.686 0.019 −2.679 −0.557 −0.839
p 5 Y′′ 0.162 −0.882 −0.821 0.164 −2.741 0.546
p 6 Z′′′ −0.634 0.230 −1.398 −0.388 −0.233 −2.798