Skip to main content
. 2021 Mar 22;14(3):441–447. doi: 10.4103/aer.AER_1_21

Table 3.

Comparison of mean change in hemodynamic parameters from baseline to 1 min among responders

Study parameters Mean change (mean±SD) P1
SBP (mm of Hg) 5.54±3.81 0.0001*
DBP (mm of Hg) 4.16±4.87 0.0001*
MAP (mm of Hg) 4.57±3.52 0.0001*
HR (beats/min) 6.54±3.34 0.0001*
cSVC (%) 4.19±3.23 0.0001*
dIVC (%) 0.28±5.68 0.80
LVOTd (mm) 0.05±0.04 0.0001*
LVOT-VTI (mm) 2.67±2.91 0.0001*
CI (L/min/m2) 0.53±0.18 0.0001*

Wilcoxon rank sum test, *Significant. cSVC=Collapsibility index of superior vena cava, dIVC=Distensibility index of inferior vena cava, LVOTd=Diameter of left ventricular outlet tract, LVOTVTI= Velocity time integral of left ventricular outlet tract, CI=Cardiac index, SBP=Systolic blood pressure, DBP=Diastolic blood pressure, MAP=Mean arterial pressure, HR=Heart rate, SD=Standard deviation