Skip to main content
. 2021 Mar 22;14(3):441–447. doi: 10.4103/aer.AER_1_21

Table 5.

Predictive values of distensibility index of inferior vena cava for responders and nonresponders

Responders, n (%) Nonresponders, n (%) Total, n (%)
dIVC cutoff
 <25% 13 (43.3) 2 (6.7) 15 (50.0)
 ≥25% 11 (36.7) 4 (13.3) 15 (50.0)
 Total 24 (80.0) 6 (20.0) 30 (100.0)
Predictive values, % (95% CI)
 Sensitivity 54.2 (34.2-74.1)
 Specificity 66.7 (28.9-104.4)
 PPV 86.7 (69.5-103.9)
 NPV 26.7 (4.3-49.0)
 AUC (95% CI) 0.66 (0.44-0.89)

Percentage from total number of cases. dIVC=Distensibility index of inferior vena cava, CI=Confidence interval, NPV=Negative predictive value, PPV=Positive predictive value, AUC=Area under the curve