Table 2. Adequate protection rate, their fit factor, and leakage rate according to N95 respirators and KF94 masks.

Tested value Overall N95 respirators KF94 masks P value OR
Overall 3M1860 3M9210+ 201 500 C250 Overall A B C D E F
Fit factor 84.4
Pass rate, % (No.) 22.7 (75) 48.7 (73) 70.0 (21) 96.7 (29) 10.0 (3) 30.0 (9) 36.7 (11) 1.1 (2) 0 (0) 6.7 (2) 0 (0) 0 (0) 0 (0) 0 (0) < 0.001a
Fit factor, Median (IQRs) 9 (3.8–92.3) 94.0 (21.5–200.0) 160.5 (86.8–200.0) 200 (200.0–200.0) 11.5 (5.0–41.0) 21.5 (10.5–179.5) 84.0 (66.0–118.3) 4.0 (2.0–8.0) 3.0 (2.0–6.0) 8.5 (4.0–26.0) 2.0 (2.0–4.0) 2.5 (2.0–3.3) 6.0 (4.0–9.5) 7.0 (4.0–15.5) < 0.001b
Leakage rate, % 25.3
Pass rate, % (No.) 20.6 (68) 42.0 (63) 53.3 (16) 93.3 (28) 10.0 (3) 36.7 (11) 16.7 (5) 2.8 (5) 0 (0) 6.7 (2) 0 (0) 0 (0) 6.7 (2) 3.3 (1) < 0.001a
Leakage rate, Median (IQRs) 20.9 (6.0–54.9) 6.0 (2.3–12.5) 4.1 (2.2–7.9) 2.0 (0.8–3.1) 15.4 (7.5–38.0) 6.1 (1.3–11.9) 7.2 (5.8–13.5) 49.0 (23.8–73.2) 50.7 (31.0–82.3) 32.3 (15.9–50.1) 60.4 (49.7–83.7) 71.5 (62.6–91.4) 28.7 (11.0–46.3) 30.5 (18.4–54.6) < 0.001b

OR = odds ratio, IQR = interquartile range.

aχ2 test for comparing N95 respirators with KF94 masks; bWilcoxon signed rank test for comparing N95 respirators with KF94 masks.