Table 3:
Mean (95% CI) Ganglion Cell Complex thickness by classification from high density 6x6 mm2 scans. Significance is determined by linear mixed-effects models.
| Ganglion Cell Complex Thickness (μm) | ||||
|---|---|---|---|---|
| Sector | Healthy eyes | Glaucoma Suspect eyes |
Glaucoma eyes | Adjusted P-value |
| All (Field) | 99.5 (96.3, 102.7) | 92.9 (87.6, 98.1) | 79.9 (78.0, 81.8) | <0.001 +, ⍰ |
| Superior Hemifield | 98.8 (95.3,102.2) | 91.7(86.0,97.4) | 80.9(78.8,82.9) | <0.001 +, ⍰ |
| Inferior Hemifield | 100.2 (96.7,103.7) | 94.1(88.3,99.8) | 78.7(76.6,80.9) | <0.001 +, ⍰ |
| All (inner ring) | 107.4(103.3,111.5) | 100.7(94.0,107.5) | 88.3(85.8,90.8) | <0.001 +, ⍰ |
| All (outer ring) | 99.1(95.8,102.3) | 92.5(87.1,97.9) | 79.3(77.3,81.2) | <0.001 +, ⍰ |
Mixed model statistical significance (p<0.05): Statistical significance
Healthy vs. Suspect
Healthy vs. Glaucoma
Suspect vs. Glaucoma