Skip to main content
Journal of Environmental Health Science and Engineering logoLink to Journal of Environmental Health Science and Engineering
. 2021 Apr 24;19(1):997–1004. doi: 10.1007/s40201-021-00664-3

Comparing the performance of the conventional and fixed‐bed membrane bioreactors for treating municipal wastewater

Hamidreza Khastoo 1, Amir Hessam Hassani 2, Roya Mafigholami 1,✉, Rouhallah Mahmoudkhani 3
PMCID: PMC8172747  PMID: 34150287

Abstract

Membrane bioreactor (MBR) is relatively a new technology in wastewater treatment. It can efficiently remove soluble and suspended organics. However, it may constantly encounter bio-fouling and cannot efficiently remove nutrient pollutants. These two deficiencies have motivated researchers to upgrade the design and operation of conventional MBR (CMBR). This study evaluates the performance of hybrid fixed bed MBR (FBMBR) treating real domestic wastewater in different operational conditions. It also compares the experimental results of FBMBR with the CMBR. For this purpose, two identical reactors are constructed as CMBR and FBMBR. Each module contains the net volume of 140 L and is operated continuously in two aerobic (DO > 4 mg/L) and anoxic (DO < 1 mg/L) conditions with average organic loading rates (OLRs) of 0.58, 0.71 and 1.55 kgCOD/m3d. The pore sizes of flat sheet membranes are 0.2–0.8 μm with total surface area of 1.4m2 per module. The experimental results revealed that the removal efficiencies of BOD, COD and TSS are above 95 % in both CMBR and FBMBR in all operating conditions. However, fouling occurs with lower rates in FBMBR. The growing rate of transmembrane pressure (TMP) in aerobic condition is 1.7mBar/day in CMBR, while it reduces to 1.2mBar/day for FBMBR in solid retention time (SRT) of 75 days and OLR of 0.58 and 0.71 kgCOD/m3d. In anoxic condition with SRT of 100 days and OLR of 1.55 kgCOD/m3d, the TMP in FBMBR is 59 % of CMBR. In addition, total nitrogen (TN) removal is between 12 % (aerobic) and 27 % (anoxic) in CMBR, while it is between 25 % (aerobic) and 49 % (anoxic) in FBMBR. Total phosphorous (TP) removal also ranges between 50 and 66 % in CMBR, while it is between 51 and 86 % in FBMBR. Consequently, using hybrid systems of FBMBR can reduce membrane fouling rate and improve nutrient removal efficiency in comparison with CMBR. This approach can reinforce the biological treatment efficiency and preserve permeate quality in higher OLRs or in lower DO level.

Keywords: Biofilm, Fouling, Hybrid, Membrane bioreactor (MBR), Wastewater treatment

Introduction

Membrane bioreactor (MBR) is relatively a new technology in wastewater treatment. The main advantage of this system in comparison with the conventional treatment units, like activated sludge process (ASP), is the application of membrane filtration instead of settling tanks. The microfilteration or ultrafilteration in MBR can separate and reject the solid from liquid phase and discharges clarified permeate with relatively higher quality (Asif et al. 2019). As Kitanou et al. (2018) have recently investigated in full scale, the concentrations of pollutants, such as biochemical oxygen demand (BOD), chemical oxygen demand (COD), and total suspended solids (TSS) are relatively lower in the effluent of MBR than ASP. MBR has also the potential of receiving higher organic loads, withstand the fluctuations of organic loading rates (OLRs), and reduce excess sludge production (Asif et al. 2019; Park et al. 2015). In addition, MBR can maintain microbial consortium with high solid retention time (SRT) for reinforcing biological treatment against shock loads or toxics, particularly in industrial wastewater treatment (Awan et al. 2015). This capability is widely received the attentions of researchers for micro and emerging pollutants removal from wastewater, like pharmaceutical compounds (Goswami et al. 2018; Gu et al. 2018; Xiao et al. 2019). However, MBR has some shortcomings that confine its applicability, including membrane fouling or its efficiency in nutrients removal.

MBR can be used for low-strength and domestic wastewater treatment. Khan et al. (2019) have recently verified that submerged aerobic MBR with 15–80 days SRT can reach 90-95 % COD removal just in 4 h hydraulic retention time (HRT). In this condition, the nitrification is totally carried out and the total phosphorous (TP) removal reaches 80 %. Gurung et al. (2017) also approved that submerged aerobic MBR with 25–30 days SRT can achieve more than 90 % COD and TP removal in system with 35 h HRT. In these systems, aeration is used for both biological oxidation and air scouring to prevent or reduce membrane fouling (Lin et al. 2014). In spite of high organic removal efficiency of MBR, the biological removal of nutrients, such as total nitrogen (TN), is a matter of controversy for safe operation of MBR for water reclamation and reuse (Jamshidi 2019). In first point of view, MBR similarly to other aerated biological treatment units requires anoxic and anaerobic conditions for TN and TP removal, respectively (Buha et al. 2017). Bezirgiannidis et al. (2017) believe that the efficiency of denitrification is below 25 % in MBR due to the absence of anoxic condition and external carbon source. Thus, the aerated MBR imposes adverse effect on nutrient removal and limits TN removal efficiency. On the other hand, Zheng et al. (2018) claims that the biofilm layer formed on membrane is enough for nutrient removal efficiency but it may adversely impose membrane fouling in operation.

Recently, some retrofitting approaches have been proposed in literature to improve nutrient removal efficiency of MBR treating low-strength and domestic wastewater. Some approaches focus on anoxic pre treatment units, while other techniques use supplementary granular systems. For example, Alighardashi et al. (2017) have proposed granular activated carbon (GAC), as a post-treatment for MBR, to achieve TN removal efficiency of about 60 %. Zhang et al. (2017) recommended bio carriers, as pre-treatment unit, to simultaneously improve TN removal efficiency and reduce organic loading rate (OLR). They concluded that high stability of biofilm in bio carriers can improve organic pollutant degradation and improves membrane fouling control. This is due to the fact that OLR reduction is directly effective on trans-membrane pressure (TMP) and membrane fouling reduction (Zeeshan et al. 2017). Similarly, Kwak et al. (2020) proposed to use Anamox before fluidized bed MBR to achieve about 82 % TN removal efficiency. Cuevas-Rodríguez et al. (2015) testified hybrid systems with fluidized and fixed bed as pre-treatment units of MBR. They concluded that fixed bed system, as the pre-treatment of MBR, is the most efficient configuration for nutrient removal. Deng et al. (2016) developed a sponge moving bed bioreactor, as pre-treatment of MBR, and claimed that this approach can enhance wastewater treatability and improve nutrient removal efficiency. In a review by Xiao et al. (2019), it is concluded that using hybrid systems as the pre-treatment of MBR can ensure > 80 % TN removal. Mannina et al. (2018) also recommended that TN and TP removal efficiency can be increased in MBR by using fixed bed media in the reactor.

This study aims on evaluating and comparing the performance of fixed bed MBR (FBMBR) in different operating scenarios for domestic wastewater treatment. For this purpose, the study is carried out in pilot scale where the porous media is submerged in the main reactor of MBR, in contrary to previous literature. Real domestic wastewater is inoculated continuously to the pilot where the main analytical pollutants are BOD, COD, TSS, TN, and TP removal efficiencies in addition to the fouling controlled by TMP. The operating scenarios testify the impacts of OLR and aeration condition on the performance of FBMBR, comparing with MBR. Finally, this paper discusses and compares the experimental outcomes with other recent and similar literature.

Materials and methods

Pilot study

This study evaluated and compared the performance of FBMBR with the conventional MBR in pilot scale. Here, the two reactors of FBMBR and MBR were designed similarly and operated in same conditions. Both reactors had net volume of 140 L constructed with plexiglass with 42 cm length, 35 cm width, and 100 cm depth and was continuously fed with real domestic wastewater extracted from the effluent of the grit chamber of Ekbatan wastewater treatment plant (WWTP), western Tehran, Iran (Fig. 1). The feeding sludge was inoculated to both reactors from the returned activated sludge of this WWTP with initial concentration of 1500 mg/L. The start-up period has taken 2 weeks where COD removal reached to steady state. Both systems were equipped with flow-meter, pressure gauge, and four flat sheet membranes. The membranes were made of polyvinylidene fluoride (PVDF) 12 % with nominal pore size of 0.2–0.8 μm (Fig. 2). By referring to Judd (2016), this nominal pore size and membrane material is the most prevalent configuration in MBR studies. Each membrane had 0.35 m2 area on both sides (70 cm length and 25 cm width) submerged in reactor with total surface area of 1.4m2 per module. The maximum functional pressure was also set on 0.5 mBar for overhaul and membrane cleaning as recommended by Xiao et al. (2019). Effluent was extracted from the system through a negative pressure on the membrane using a volumetric pump (Alighardashi et al. 2017). Media used for FBMBR was made of polyvinyl chloride (PVC) with density of 26 kg/m3 and 420 μm thickness. It had the nominal specific area of 200m2 and 4400 m2/m3 media, which was similarly used in previous studies as Valipour et al. (2014).

Fig. 1.

Fig. 1

Pilot configuration

Fig. 2.

Fig. 2

SEM image of membranes used in this study

Operating scenarios

Pilots were operated without relaxations for more than 3 months in ambient temperature of 20–28 ͦ C with constant permeate flux and variable TMP as more preferred by Iorhemen et al. (2016). Four different operating conditions were tested in this period as shown in Table 1. In start-up and S1, both pilots were operated with average OLR of 0.58 kgCOD/m3d for 35 days which is similar to the operating OLR condition of Cuevas-Rodríguez et al. (2015) with 0.51 kgCOD/m3d. In S1, the aeration was high (DO > 4 mg/L) where the sludge has been partially digested in MBR, while its concentration was increased in FBMBR. In S2 and S3, the average OLR increased to 0.71 kgCOD/m3d for a period of 40 days. In S2, the aeration was similar to S1, while the reactors were operated in anoxic condition (DO < 1 mg/L) in S3 (Akbarzadeh et al. 2015; Wang et al. 2021). In these operating conditions, it was observed that the rate of increasing sludge concentration in MBR was more rapid than FBMBR. It could be due to the partial formation of biofilms, instead of flocs, in FBMBR that reduced suspended MLVSS in main bioreactor. Finally, the operation was continued for 25 days in S4 where the OLR jumped to 1.55 kgCOD/m3d. In these scenarios, OLRs were adjusted by decreasing HRT from 24 to 6 h. Table 2 summarizes the influent characteristics and its variations in the study period. The influent was extracted from the effluent of grit chamber in Ekbatan WWTP and analyzed twice per week.

Table 1.

Operational conditions and scenarios of two pilots

Period (days) Scenario OLR (kgCOD/m3d) DO (mg/L) MLVSS (mg/L)
MBR FBMBR
1–14 Start-up 0.58 > 4 1360 1680
14–35 S1 0.58 > 4 1840 2040
35–60 S2 0.71 > 4 2040 1800
60–75 S3 0.71 < 1 2520 2160
75–100 S4 1.55 < 1 2680 2040

Table 2.

Influent characteristics in the study period (out of 32 samples)

Parameter Mean Min. Max.
BOD (mg/L) 269 180 343
COD (mg/L) 525 293 625
TSS (mg/L) 281 198 368
TDS (mg/L) 456 394 554
TP (mg/L) 6.5 6.1 7.2
TKN (mg/L) 57 38 76
pH 8.2 7.3 8.9

Sampling and test

Samples were taken weekly from both, the influent and membrane permeate. BOD was tested by BODTrakTM according to the standard methods (APHA 2017). COD, phosphate, ammonium, nitrite and nitrate were tested by DR5000 and HACK methods, and TSS was tested by ASTM 5907 (2018). MLVSS was tested by 2540 E standard method (APHA 2017) similar to Ebrahimi et al. (2018). Other parameters, such as DO, pH, and temperature were controlled in pilot study while TMP was also recorded daily for tracking membrane fouling.

Results and discussion

The first outcome of pilot study in four consecutive steps shows that the TMP rises by increasing OLR (Fig. 3). It means that the enhancement of organics concentrations, or HRT reduction, can develop the probability of membrane fouling in MBR. In addition, high instantaneous flux can lead into rapid fouling in MBR as similarly verified by Habib et al. (2017) and Zeeshan et al. (2017). Likewise, Iorhemen et al. (2016) concluded that instantaneous decrease of HRT can result in the enhancement of extracellular polymeric substances (EPS) production, and hence severe fouling. However, this study reveals that using fixed bed in the main reactor of MBR (FBMBR) can significantly reinforce the membrane against rapid fouling in comparison with the conventional MBR. For example, in three months, the identical reactor of FBMBR had 50 % less TMP than MBR. It is mainly due to partial entrapment of organic compounds by the fixed bed, less EPS concentration and sludge production yield of biofilm in comparison with conventional MBR. In first three scenarios of S1, S2 and S3 (SRT < 75 days), the increasing rate of TMP was 1.7 mBar/day for MBR, while it was 1.2 mBar/day for FBMBR. By considering S4 in calculations (SRT < 100 days), the increasing rate of TMP was 4.4 mBar/day for MBR, while it was 2.1 mBar/day for FBMBR. Iorhemen et al. (2016) have concluded that operating MBR with SRTs above 50 days tends to increase fouling. However, this study emphasizes that OLR is more effective on fouling than SRT. It can be due to the fact that decreasing HRT (equals increasing OLR) can increase the forces on membranes for permeating higher volumes of liquid per day. It leads into the domination of bio-fouling over air scouring and consequently cause an abrupt increase of TMP as observed in S4.

Fig. 3.

Fig. 3

Organic loading rate (OLR) and trans-membrane pressures (TMP) of two pilots in study period

In addition to the advantage of less TMP, Fig. 4 shows that the overall BOD, COD and TSS removal efficiency of FBMBR remain rather constant above 95 % in all operating scenarios. Even in high OLR of 1.55 kgCOD/m3d, BOD and COD removal efficiency is above 97 %. It means that different operational conditions, such as low HRTs or anoxic condition, may not deteriorate the permeate concentrations of FBMBR.

Fig. 4.

Fig. 4

BOD, COD and TSS removal efficiency of FBMBR in study period

Another advantage of FBMBR in comparison with MBR is its performance in TN and TP removal. The conventional MBR, like activated sludge systems, has no specific capability for nutrients removal unless the anoxic/anaerobic conditions are dominated in main reactor with effluent recirculation (Miyoshi et al. 2018). However, these conditions may adversely reduce the membrane scouring which is typically carried out by aeration. Aeration plays a dual role in aerobic MBRs. It supplies oxygen for the biological processes and serves as a way of dislodging the cake layer formed on the membrane surface (Iorhemen et al. 2016). Hence, the membrane fouling can be increased or accelerated. Nevertheless, the aforementioned results show that FBMBR is relatively reinforced against accelerated fouling in different operating conditions and show little adverse reaction in organics (BOD and COD) and TSS removal.

Figures 5 and 6 illustrate that FBMBR can develop nutrient removal in different operating conditions including aerobic/anoxic or high OLRs. For example, in S1 and S2, the average TN removal is higher in FBMBR about 9 and 22 %, respectively (P value < 0.05) where the DO is above 4 mg/L. However, TP removal is rather constant in both reactors in these two operating scenarios (P value > 0.05) as anaerobic condition can rarely be dominated, even in biofilms. It means that the application of porous fixed bed in the main reactor of MBR can improve TN removal and reinforce its performance in higher OLRs in aerobic hybrid bioreactor. Likewise to the prediction of Mahdavi et al. (2018), nutrient removal efficiency and denitrification are higher in S1 in comparison with S2 as the HRT is greater in S1. Figure 7 illustrates the statistical 95 % confidence interval bars plotted by Minitab 19 software. The analysis of variance (ANOVA) was used to compare the experimental results of TN and TP removal in FBMBR and MBR in two scenarios of S1 and S2. It schematically verifies that TN removal is more considerable in FBMBR, while TP removal is not significantly different.

Fig. 5.

Fig. 5

TN removal efficiency (%) in FBMBR and MBR in four operating scenarios

Fig. 6.

Fig. 6

TP removal efficiency (%) in FBMBR and MBR in four operating scenarios

Fig. 7.

Fig. 7

Statistical 95 % confidence interval bars plotted for TN (left) and TP (right) removal (%) in FBMBR and MBR in two scenarios (S1, S2)

TN removal efficiency also improves in S3 and S4 about 14 and 22 %, respectively where anoxic condition is dominated in main reactor. Figure 5 demonstrates that the conventional MBR can improve its TN removal only when anoxic condition is dominated (S3 and S4). Nonetheless, FBMBR relatively performs more efficiently both in aerobic (S1 and S2) and anoxic (S3 and S4) conditions. It also comparatively performs more reliably in higher OLRs (S2 and S4).

Therefore, the comparative results show that using fixed media can develop the efficiency of conventional MBR, particularly for TN and TP removal. It can be due to the fact that biofilm is formed that contains both nitrifying and denitrifying bacteria as a matter of oxygen gradient within this layer (Valipour et al. 2014).

Rodriquez-Hernandez et al. (2014) have similarly compared the performance of hybrid MBR (HMBR) and conventional MBR (CMBR) using a pilot study. Their pilot was constructed vertically with 1.8 m3 volume having membranes with nominal pore size of 0.4 μm. These pilots were operated for 75 days with real municipal wastewater in three OLR scenarios of 0.83, 1.15 and 2.2 kgCOD/m3d. These specifications and operating conditions are close to the current study where OLR ranges between 0.58 and 1.6 kgCOD/m3d. However, Rodriquez-Hernandez et al. (2014) used effluent recirculation for improving nutrient removal. COD removal in CMBR and HMBR were 80 and 84 %, respectively while these values for BOD were 96 and 98 %, respectively. These values are > 95 % in the present study. They also concluded that nutrient removal is relatively higher in HMBR due to simultaneous aerobic, anoxic and anaerobic conditions in biofilm. TN removal in HMBR and CMBR were reported 75 and 38 %, respectively as concluded the biofilm could simultaneously carry out nitrification and denitrification. TN removal in the current study ranges between 25 and 49 % for FBMBR, while these values range between 12 and 27 % in conventional MBR. Phosphate removal in HMBR and CMBR were 42 and 37 %, respectively, while TP removal is between 50 and 87 % in the current study. Rodriquez-Hernandez et al. (2014) also concluded that the fouling rate in HMBR was 57 % of CMBR which this ratio is 59 % on average in this study. Palmarin and Young (2019) have also testified the performance of fluidized bed in HMBR with 8 h HRT to control pollutant removal efficiency from grey water. They concluded that HMBR is able to achieve pollutant removal efficiency equal or greater than MBR as similarly concluded in this study as well. In HMBR, biocarriers can noticeably improve the nitrification and denitrification processes. TN removal was between 60 and 71 %, TP and COD removal were about 90 % and BOD removal exceeds 96 %. These values are relatively the same as the current study except TN removal which is higher than the current study as Rodriquez-Hernandez et al. (2014). Zhang et al. (2017) in 140 days operation of MBR with moving bed as pre-treatment unit, 20Kpa TMP and hollow fiber membrane with 0.2 μm nominal pore size, could reach 50 % TN removal while COD removal exceeds 95 %. Izadi et al. (2019) have evaluated the performance of vertical FBMBR in low strength paper-recycling wastewater. The pilot was operated in 36 h HRT (OLR: 0.9–1.1 kgCOD/m3d) and membrane had nominal pore size of 0.4 μm with 0.1 m2 surface area. They concluded that COD and TN removal efficiencies were between 92 and 99 % and 68–92 %, respectively. Therefore, regarding the experimental outcomes of this study and similar researches, it is hard to approve that the conventional aerated MBR can reach 90 % TN removal efficiency without any pre-treatment or supplementary unit as claimed by Kitanou et al. (2018). In addition, Schmitt et al. (2018) recommended that the evolution of TMP can be predicted by TN or TP, while these parameters have no direct impacts on membrane fouling. Conversely, TN and TP removal can be improved by high TMP as claimed by Zheng et al. (2018). Consequently, using any predictions by neural network modeling is not recommended, unless the role of each parameter and related causes are initially highlighted as similarly carried out by Gholikandi et al. (2014) for anaerobic treatment of municipal wastewater. With respect to the short review on new approaches of retrofitting aerobic and anaerobic wastewater treatment units, it can recommend that MBR may has the potential of being upgraded with electrochemical techniques for fouling control (Naderi Varandi et al. 2017).

Conclusions

According to the experimental results of two identical pilots of FBMBR and MBR in different operational conditions, it can be concluded that the application of fixed bed in the main reactor can improve the removal efficiency and operational performance of MBRs treating domestic wastewater. The hybrid system of FBMBR comparatively has lower fouling rate and more TN and TP removal efficiency. This performance is repeated in both aerobic and anoxic conditions and verified in both low and high OLRs. Therefore, the presence of support media is highly recommended to improve the MBR performance.

Footnotes

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

References

  1. Akbarzadeh A, Jamshidi S, Vakhshouri M. Nutrient uptake rate and removal efficiency of Vetiveria zizanioides in contaminated waters. Pollution. 2015;1(1):1–8. [Google Scholar]
  2. Alighardashi A, Pakan M, Jamshidi S, Shariati FP. Performance evaluation of membrane bioreactor (MBR) coupled with activated carbon on tannery wastewater treatment. Membr Water Treat. 2017;8(6):517–28. doi: 10.12989/mwt.2017.8.6.517. [DOI] [Google Scholar]
  3. APHA. Standard methods for the examination of water and wastewater, 23rd ed. Washington DC: American Public Health Association; 2017.
  4. Asif MB, Hai FI, Jegatheesan V, Price WE, Nghiem LD, Yamamoto K. Chap. 8 - Applications of membrane bioreactors in biotechnology processes Editor(s): Basile A. and Charcosset C., Current Trends and Future Developments on (Bio-) Membranes, Elsevier, 2019; p. 223–257.
  5. ASTM D5907-18 . Standard test methods for filterable matter (total dissolved solids) and nonfilterable matter (total suspended solids) in water. West Conshohocken: ASTM International; 2018. [Google Scholar]
  6. Awan SF, Zhang B, Zhong Z, Gao L, Chen X. Industrial wastewater treatment by using MBR (Membrane Bioreactor) review study. J Environ Prot. 2015;6(6):584–98. doi: 10.4236/jep.2015.66053. [DOI] [Google Scholar]
  7. Bezirgiannidis A, Marinakis N, Ntougias S, Melidis P. Biological treatment of a low strength domestic wastewater in a membrane bioreactor. Eur Water. 2017;58:83–6. [Google Scholar]
  8. Buha DM, Atalia KR and Shah NK. Continuous process study on simultaneous nitrification–denitrification of high ammoniacal nitrogen load wastewater in aerobic–anoxic sequencing bioreactors. Int J Environ Sci Technol 2017;14:2451–2458.
  9. Cuevas-Rodríguez G, Cervantes-Avilés P, Torres-Chávez I, Bernal-Martínez A. Evaluation of different configurations of hybrid membrane bioreactors for treatment of domestic wastewater. Water Sci Technol. 2015;71(3):338–46. doi: 10.2166/wst.2014.481. [DOI] [PubMed] [Google Scholar]
  10. Deng L, Guo W, Ngo HH, Zhang X, Wang XC, Zhang Q, Chen R. New functional biocarriers for enhancing the performance of a hybrid moving bed biofilm reactor–membrane bioreactor system. Biores Technol. 2016;208:87–93. doi: 10.1016/j.biortech.2016.02.057. [DOI] [PubMed] [Google Scholar]
  11. Ebrahimi M, Gholikandi GB, Jamshidi S, Ezzo H. Dolomite reactor, a retrofitting approach for activated sludge against bulking. Iran J Sci Technol Trans A Sci. 2018;42:1215–21. doi: 10.1007/s40995-016-0120-x. [DOI] [Google Scholar]
  12. Gholikandi GB, Jamshidi S, Hazrati H. Optimization of anaerobic baffled reactor (ABR) using artificial neural network in municipal wastewater treatment. Environ Eng Manag J. 2014;13(1):95–104. doi: 10.30638/eemj.2014.012. [DOI] [Google Scholar]
  13. Goswami L, Kumar RV, Borah SN, Manikandan NA, Pakshirajan K, Pugazhenthi G. Membrane bioreactor and integrated membrane bioreactor systems for micropollutant removal from wastewater: A review. J Water Process Eng. 2018;26:314–28. doi: 10.1016/j.jwpe.2018.10.024. [DOI] [Google Scholar]
  14. Gu Y, Huang J, Zeng G, Shi L, Shi Y, Yi K. Fate of pharmaceuticals during membrane bioreactor treatment: Status and perspectives. Biores Technol. 2018;268:733–48. doi: 10.1016/j.biortech.2018.08.029. [DOI] [PubMed] [Google Scholar]
  15. Gurung K, Ncibi MC, Sillanpa M. Assessing membrane fouling and the performance of pilot-scale membrane bioreactor (MBR) to treat real municipal wastewater during winter season in Nordic regions. Sci Total Environ. 2017;579:1289–97. doi: 10.1016/j.scitotenv.2016.11.122. [DOI] [PubMed] [Google Scholar]
  16. Habib R, Asif MB, Iftekhar S, Khan Z, Gurung K, Sillanpaa M. Influence of relaxation modes on membrane fouling in submerged membrane bioreactor for domestic wastewater treatment. Chemosphere. 2017;181:19–25. doi: 10.1016/j.chemosphere.2017.04.048. [DOI] [PubMed] [Google Scholar]
  17. Iorhemen OT, Hamza RA, Tay JH. Membrane Bioreactor (MBR) technology for wastewater treatment and reclamation: membrane fouling. Membranes. 2016;6:33. doi: 10.3390/membranes6020033. [DOI] [PMC free article] [PubMed] [Google Scholar]
  18. Izadi A, Hosseini M, Darzi GN, Bidhendi GN, Shariati FP. Performance of an integrated fixed bed membrane bioreactor (FBMBR) applied to pollutant removal from paper-recycling wastewater. Water Resour Ind. 2019;21:100111. doi: 10.1016/j.wri.2019.100111. [DOI] [Google Scholar]
  19. Jamshidi S. Value-added innovation in infrastructure systems, lessons learned from wastewater treatment plants. TQM J. 2019;31(6):1049–63. doi: 10.1108/TQM-11-2018-0178. [DOI] [Google Scholar]
  20. Judd SJ. The status of industrial and municipal effluent treatment with membrane bioreactor technology. Chem Eng J. 2016;305:37–45. doi: 10.1016/j.cej.2015.08.141. [DOI] [Google Scholar]
  21. Khan SJ, Hasnain G, Fareed H, Aim RB. Evaluation of treatment performance of a full-scale membrane bioreactor (MBR) plant from unsteady to steady state condition. J Water Process Eng. 2019;30:100379. doi: 10.1016/j.jwpe.2017.03.004. [DOI] [Google Scholar]
  22. Kitanou S, Tahri M, Bachiri B, Mahi M, Hafsi M, Taky M, Elmidaoui A. Comparative study of membrane bioreactor (MBR) and activated sludge processes in the treatment of Moroccan domestic wastewater. Water Sci Technol. 2018;78(5):1129–36. doi: 10.2166/wst.2018.384. [DOI] [PubMed] [Google Scholar]
  23. Kwak W, Rout PR, Lee B, Bae J. Influence of hydraulic retention time and temperature on the performance of an anaerobic ammonium oxidation fluidized bed membrane bioreactor for low-strength ammonia wastewater treatment. Chem Eng J. 2020;386:123992. doi: 10.1016/j.cej.2019.123992. [DOI] [Google Scholar]
  24. Lin H, Zhang M, Wang F, Meng F, Liao BQ, Hong H, Chen J, Gao W. A critical review of extracellular polymeric substances (EPSs) in membrane bioreactors: Characteristics, roles in membrane fouling and control strategies. J Membr Sci. 2014;460:110–25. doi: 10.1016/j.memsci.2014.02.034. [DOI] [Google Scholar]
  25. Mahdavi SZ, Razavi SMR, Shirazian S. Mathematical modeling and simulation of nitrate separation from contaminated water in a membrane contactor. Iran J Sci Technol Trans A Sci. 2018;42:1223–31. doi: 10.1007/s40995-016-0058-z. [DOI] [Google Scholar]
  26. Mannina G, Ekama GA, Capodicia M, Cosenza A, Trapani DD, Ødegaard H. Integrated fixed-film activated sludge membrane bioreactors versus membrane bioreactors for nutrient removal: A comprehensive comparison. J Environ Manag. 2018;226:347–57. doi: 10.1016/j.jenvman.2018.08.006. [DOI] [PubMed] [Google Scholar]
  27. Miyoshi T, Tsumuraya T, Nguyen TP, Kimura K, Watanabe Y. Effects of recirculation and separation times on nitrogen removal in baffled membrane bioreactor (B-MBR) Water Sci Technol. 2018;77(12):2803–11. doi: 10.2166/wst.2018.270. [DOI] [PubMed] [Google Scholar]
  28. Naderi Varandi B, Jamshidi S, Mennerich A, Sadeghi Azad A. Electrolysis enhanced anaerobic baffled reactor as retrofitting approach for molasses based distillery wastewater treatment. Desalin Water Treat. 2017;62:80–5. doi: 10.5004/dwt.2017.20144. [DOI] [Google Scholar]
  29. Palmarin MJ, Young S. Comparison of the treatment performance of a hybrid and conventional membrane bioreactor for greywater reclamation. J Water Process Eng. 2019;28:54–9. doi: 10.1016/j.jwpe.2018.12.012. [DOI] [Google Scholar]
  30. Park HD, Chang IS, Lee KJ. Principles of membrane bioreactors for wastewater treatment. Boca Raton: CRC Press; 2015. [Google Scholar]
  31. Rodríguez-Hernández L, Esteban-García AL, Tejero I. Comparison between a fixed bed hybrid membrane bioreactor and aconventional membrane bioreactor for municipal wastewatertreatment: A pilot-scale study. Biores Technol. 2014;152:212–9. doi: 10.1016/j.biortech.2013.10.081. [DOI] [PubMed] [Google Scholar]
  32. Schmitt F, Banu R, Yeom IC, Do KU. Development of artificial neural networks to predict membrane fouling in an anoxic aerobic membrane bioreactor treating domestic wastewater. Biochem Eng J. 2018;133:47–58. doi: 10.1016/j.bej.2018.02.001. [DOI] [Google Scholar]
  33. Valipour A, Taghvaei SM, Raman VK, Gholikandi GB, Jamshidi S, Hamnabard N. An approach on attached growth process for domestic wastewater treatment. Environ Eng Manag J. 2014;13(1):145–52. doi: 10.30638/eemj.2014.018. [DOI] [Google Scholar]
  34. Wang L, Li B, Li Y, Wang J. Enhanced biological nitrogen removal under low dissolved oxygen in an anaerobic-anoxic-oxic system: Kinetics, stoichiometry and microbial community. Chemosphere. 2021;263:128184. doi: 10.1016/j.chemosphere.2020.128184. [DOI] [PubMed] [Google Scholar]
  35. Xiao K, Liang S, Wang X, Chen C, Huang X. Current state and challenges of full-scale membrane bioreactor applications: A critical review. Biores Technol. 2019;271:473–81. doi: 10.1016/j.biortech.2018.09.061. [DOI] [PubMed] [Google Scholar]
  36. Zeeshan M, Haydar S, Tabraiz S. Effect of fixed media surface area on biofouling and nutrients removal in fixed film membrane bioreactor treating sewage at medium and high fluxes. Water Air Soil Pollut. 2017;228:377. doi: 10.1007/s11270-017-3550-y. [DOI] [Google Scholar]
  37. Zhang W, Tang B, Bin L. Research progress in biofilm-membrane bioreactor: a critical review. Ind Eng Chem Res. 2017;56(24):6900–9. doi: 10.1021/acs.iecr.7b00794. [DOI] [Google Scholar]
  38. Zheng Y, Zhang W, Tang B, Ding J, Zheng Y, Zhang Z. Membrane fouling mechanism of biofilm-membrane bioreactor (BF-MBR): pore blocking model and membrane cleaning. Biores Technol. 2018;250:398–405. doi: 10.1016/j.biortech.2017.11.036. [DOI] [PubMed] [Google Scholar]

Articles from Journal of Environmental Health Science and Engineering are provided here courtesy of Springer