Skip to main content
. 2021 Jun 2;11:11589. doi: 10.1038/s41598-021-90349-6

Table 1.

Size (radius) and polydispersity percentage (Pd %) of the control and Tf-PEG liposomes following the 3rd and 6th LFUS pulses. Results are the average of three batches.

Before sonication After 3rd pulse After the 6th pulse
6.2 mW/cm2 9 mW/cm2 10 mW/cm2 6.2 mW/cm2 9 mW/cm2 10 mW/cm2
Control
Radius (nm) 87.5 ± 2.57 73.7 ± 1.14 70.8 ± 0.424 70.7 ± 1.71 66.3 ± 2.18 62.1 ± 1.58 57.2 ± 1.23
p-value 0.226 0.000387 0.000417 0.000574 0.000147 5.02 × 10–5
Pd (%) 14.1 ± 2.95 16.6 ± 0.759 16.9 ± 1.21 15.3 ± 5.61 19.8 ± 2.90 21.8 ± 2.05 22.4 ± 1.05
p-value 0.198 0.233 0.210 0.0424 0.00768 0.0120
Tf-PEG
Radius (nm) 80.5 ± 1.89 77.1 ± 1.25 76.4 ± 2.15 73.0 ± 1.25 74.1 ± 1.79 71.6 ± 2.04 69.7 ± 4.68
p-value 0.0366 0.0460 0.000579 0.000611 0.00136 0.01125
Pd (%) 9.1 ± 2.70 16.3 ± 3.88 18.6 ± 1.61 20.2 ± 2.10 21.3 ± 2.19 23.7 ± 0.063 23.9 ± 0.23
p-value 0.0364 0.00115 0.000637 0.000103 3.75 × 10–5 3.45 × 10–5