Table 1.
Size (radius) and polydispersity percentage (Pd %) of the control and Tf-PEG liposomes following the 3rd and 6th LFUS pulses. Results are the average of three batches.
Before sonication | After 3rd pulse | After the 6th pulse | |||||
---|---|---|---|---|---|---|---|
6.2 mW/cm2 | 9 mW/cm2 | 10 mW/cm2 | 6.2 mW/cm2 | 9 mW/cm2 | 10 mW/cm2 | ||
Control | |||||||
Radius (nm) | 87.5 ± 2.57 | 73.7 ± 1.14 | 70.8 ± 0.424 | 70.7 ± 1.71 | 66.3 ± 2.18 | 62.1 ± 1.58 | 57.2 ± 1.23 |
p-value | 0.226 | 0.000387 | 0.000417 | 0.000574 | 0.000147 | 5.02 × 10–5 | |
Pd (%) | 14.1 ± 2.95 | 16.6 ± 0.759 | 16.9 ± 1.21 | 15.3 ± 5.61 | 19.8 ± 2.90 | 21.8 ± 2.05 | 22.4 ± 1.05 |
p-value | 0.198 | 0.233 | 0.210 | 0.0424 | 0.00768 | 0.0120 | |
Tf-PEG | |||||||
Radius (nm) | 80.5 ± 1.89 | 77.1 ± 1.25 | 76.4 ± 2.15 | 73.0 ± 1.25 | 74.1 ± 1.79 | 71.6 ± 2.04 | 69.7 ± 4.68 |
p-value | 0.0366 | 0.0460 | 0.000579 | 0.000611 | 0.00136 | 0.01125 | |
Pd (%) | 9.1 ± 2.70 | 16.3 ± 3.88 | 18.6 ± 1.61 | 20.2 ± 2.10 | 21.3 ± 2.19 | 23.7 ± 0.063 | 23.9 ± 0.23 |
p-value | 0.0364 | 0.00115 | 0.000637 | 0.000103 | 3.75 × 10–5 | 3.45 × 10–5 |