Skip to main content
. 2021 Jun 2;9:e11521. doi: 10.7717/peerj.11521

Table 1. Reliability metrics for hip torque measurements using a custom rig.

Session 1 Session 2 ICC (95% CI) SEM (95% CI) SEM MDC (95% CI) MDC
(N.m) (N.m) (N.m) % (N.m) %
Abduction (n = 20) 95 ± 21 99 ± 24 0.77 (0.51–0.90) 11 (8–16) 11 25 (19–37) 26
Adduction (n = 20) 124 ± 29 126 ± 26 0.92 (0.79–0.97) 8 (6–12) 6 19 (14–28) 15
Extension (n = 18) 226 ± 54 210 ± 52 0.85 (0.57–0.95) 19 (14–29) 9 44 (32–68) 20
Flexion (n = 17) 87 ± 17 88 ± 17 0.95 (0.84–0.98) 4 (3–7) 5 9 (7–15) 11
Internal rotation (n = 20) 65 ± 19 65 ± 17 0.86 (0.66–0.94) 7 (5–10) 11 16 (12–24) 25
External rotation (n = 20) 48 ± 11 50 ± 13 0.72 (0.41–0.88) 6 (5–10) 13 15 (11–22) 31

Notes.

Values are mean ± standard deviation unless otherwise indicated.

ICC
intraclass correlation coefficient
CI
confidence interval
SEM
standard error of measurement
MDC
minimal detectable change
N.m
newton.metre
N
newton
E
extension
AB
abduction
ER
external rotation