Skip to main content
. 2021 May;13(5):2705–2715. doi: 10.21037/jtd-21-178

Table 2. TTFM and FFT data of graft failure and MACCEs.

Parameters* Patency (N=257) Graft failure (N=63) P MACCEs NO MACCEs P
PI 2.85±1.49 4.11±9.29 0.056 3.36±6.77 3.15±1.93 0.759
MGF 22.99±12.91 19.60±11.32 0.020 22.58±12.67 20.16±11.91 0.103
H0 43.00±13.67 33.06±8.05 <0.001 40.09±13.41 38.24±11.70 0.230
H1 3.45±1.34 2.17±1.20 <0.001 3.02±1.42 2.95±1.46 0.673
H0/H1 16.45±16.00 33.37±75.75 <0.001 23.53±17.81 20.15±22.24 0.311
P 2.46±0.94 3.14±0.81 <0.001 2.66±0.94 2.78±0.98 0.290

*, continuous variables with normal distribution are presented as mean ± SD unless otherwise noted. PI, pulse index; MGF, mean graft flow; H0, the amplitude of the main wave; H1, the amplitude of the first harmonic; P, the frequency of the first harmonic; MACCEs, major adverse cardiac and cerebrovascular events.