Skip to main content
. 2002 Aug;23(7):1214–1221.

TABLE 2:

Model parameters for the clinical patients

Patient and Run* ρconv, % ρdiff, % τconv, seconds τdiff, seconds
Patient 1
 Before stent 73.2 36.8 0.65 7.8
 After stent 34.5 65.5 1.06 18.2
Patient 2
 No devices 84.3 14.7 0.29 4.98
 One stent 82.9 17.1 0.29 4.97
 One stent and coils 89 11 0.53 4.95
 One stent and coils, after 2 mo 91.4 8.6 0.03 4.17
 Two stents and coils 69.4 30.6 0.07 5.1
Patient 3
 Before stent 53 47 1.71 15
 After stent 39 61.1 1.93 20
Patient 4
 Before stent 99 0.95 0.5 1.56
 After stent 90.3 9.7 0.53 9.71
Patient 5
 Before stent 60.2 39.8 1.22 4.97
 After stent 67 33.1 2.77 4.77