Table 2.
Test conditions for the 18 tests, representing low flow rate, medium flow rate, and high flow rate tests.
Case | Coating applied | Pin, psig | Rein | Gave, kg/m2 s | tend, s | Tin, K |
---|---|---|---|---|---|---|
1 | No coating | 100 | 63,030 | 455 | 21.0 | 95.95 |
2 | No coating | 80 | 58,909 | 436 | 21.5 | 89.82 |
3 | No coating | 60 | 35,073 | 300 | 21.55 | 90.96 |
4 | 1L coating | 100 | NA | NA | 10.6 | NA |
5 | 1L coating | 80 | 62,901 | 454 | 11.5 | 96.07 |
6 | 1L coating | 60 | 44,827 | 365 | 13.0 | 92.43 |
7 | 1L coating | 40 | 26,763 | 249 | 15.05 | 88.80 |
8 | 1L coating | 30 | 16,061 | 168 | 19.05 | 85.65 |
9 | 3L coating | 100 | 58,704 | 422 | 9.70 | 96.26 |
10 | 3L coating | 80 | 55,149 | 413 | 10.35 | 94.53 |
11 | 3L coating | 60 | 44,326 | 355 | 11.45 | 92.56 |
12 | 3L coating | 40 | 25,480 | 232 | 13.0 | 89.24 |
13 | 3L coating | 30 | 19,455 | 195 | 15.75 | 86.54 |
14 | 4L coating | 100 | 77,968 | 538 | 9.2 | 93.65 |
15 | 4L coating | 80 | 63,406 | 459 | 9.6 | 92.19 |
16 | 4L coating | 60 | 36,657 | 302 | 11.55 | 90.86 |
17 | 4L coating | 40 | 26,792 | 249 | 12.0 | 89.21 |
18 | 4L coating | 30 | 17,203 | 188 | 15.55 | 83.86 |
Conditions are based on the upstream TC station.