. 2021 Jun 8;11:12095. doi: 10.1038/s41598-021-91305-0

Table 1.

Diagnostic accuracy of the proposed CAD system. Feature selection had a significant impact on classifier performance with Friedman test χ2=32.7, 3 d.f., p=3×10-7. V: Wilcoxon signed rank statistic of performance compared to complete system; p: Associated Bonferroni-corrected p-value.

Sensitivity Specificity DSC Accuracy V p
Performance of the proposed whole CAD system
LOSO 100% ± 0.00 100% ± 0.00 100% ± 0.00 100% ± 0.00
Tenfold 100% ± 0.00 99% ± 1.00 99.50% ± 0.50 99.50% ± 0.50
Fourfold 100% ± 0.00 98% ± 2.00 99% ± 1.00 99% ± 1.00
Twofold 100% ± 0.00 97% ± 3.00 98% ± 2.00 98% ± 2.00
Performance of the proposed CAD system when using only the estimated energy at ν1
LOSO 76% ±4.29 96% ± 1.97 75% ± 4.27 86% ± 2.37 118 0.0033
Tenfold 74% ± 1.26 98% ± 4.21 83.61% ± 9.15 86% ± 7.37
Fourfold 71% ± 8.28 98% ± 2.31 81.87% ± 5.05 84.50% ± 3.41
Twofold 71% ±4.24 99% ± 1.41 80.87% ± 2.14 80.30% ± 1.41
Performance of the proposed CAD system when using only the estimated energy at ν2
LOSO 81% ± 3.94 94% ± 2.39 79.33% ± 3.93 87.5% ± 2.28 136 0.0014
Tenfold 79% ± 1.29 94% ± 5.07 85.45% ± 6.23 87% ± 4.83
Fourfold 80% ± 8.86 93% ± 6.31 83.83% ± 6.15 86.50% ± 3.41
Twofold 77% ± 1.41 91% ± 2.82 82.16% ± 2.20 85.50% ± 2.12
Performance of the proposed CAD system when using only the estimated energy at ν3
LOSO 97% ±1.71 94% ± 2.39 95% ± 1.85 95.5% ± 1.43 136 0.0014
Tenfold 93% ± 8.23 97% ± 4.83 94.78% ± 5.56 95% ± 5.27
Fourfold 92% ± 1.13 95% ± 3.83 93.16% ± 7.82 93.50% ± 7.19
Twofold 91% ±7.07 95% ± 1.41 92.79% ± 3.20 93% ± 2.82