Skip to main content
. Author manuscript; available in PMC: 2021 Jun 9.
Published in final edited form as: Nature. 2020 Dec 23;589(7842):420–425. doi: 10.1038/s41586-020-03073-y

Extended Data Table 1 |.

Participant and RNS System details

Participant number 1 2 3 4 5
Age 49 52 34 33 31
Gender female female male male male
Number of performed task blocks(1) 2 3 4 4 4
RNS Neurostimulator model RNS-300M RNS-300M RNS-320 RNS-300M RNS-300M
Electrode 1 Hemisphere left left left left left
Implant orientation(2) 0 0 0 L L
Contact spacing 3.5 mm 3.5 mm 10 mm 10 mm 10 mm
Number of MTL channels 2 2 1 2 2
Channel 1 localization(3) Sub/Sub Sub/Sub ERC/PRC HPP/Sub HPP/HPP
Channel 2 localization(3) HPP/PWM HPP/PRC Sub/Sub HPP/Sub
Electrode 2 Hemisphere right left right right right
Implant orientation(2) 0 L 0 L O
Contact spacing 10 mm 10 mm 10 mm 10 mm 10 mm
Number of MTL channels 1 2 1 2 1
Channel 1 localization(3) HPP/PRC HPP/HPP Sub/PRC HPP/Sub Sub/PWM
Channel 2 localization(3) HPP/HPP Sub/Sub
1

Each block comprised about 15 min of the self-navigation task, followed by about 15 min of the observation task.

2

L, along the longitudinal axis of the hippocampus; O, orthogonally to the long axis of the hippocampus.

3

Localization of two electrode contacts (+/−) per bipolar recording channel. ERC, entorhinal cortex; HPP, hippocampus (CA1/CA2/CA3/DG); PRC, perirhinal cortex; PWM, parahippocampal white matter; Sub, subiculum.