Skip to main content
. 2021 May 26;6(22):14481–14492. doi: 10.1021/acsomega.1c01449

Table 2. Adsorption and Desorption Rate Constants, ka and kd, of the Adsorption Systems Determined by IRA and HOA.

    parameters as per IRA
parameters as per HOA
adsorption system characteristic change in operating condition ka × 109 (m3/s) kd × 109 (kg/s) kH1 × 105 (s–1) ka × 109 (m3/s) kd × 109 (kg/s)
system 1a CA,0 = 0.001 kg/m3 182 0.48 35.1 183 0.48
system 1b CA,0 = 0.002 kg/m3 181 0.48 35.6 187 0.49
system 1c CA,0 = 0.003 kg/m3 185 0.49 35.0 184 0.48
system 2a CA,0 = 0.20 kg/m3 18.4 0.86 6.37 20.1 0.94
system 2b CA,0 = 0.30 kg/m3 16.6 0.77 4.58 16.5 0.77
system 2c CA,0 = 0.50 kg/m3 15.4 0.71 3.63 16.9 0.79
system 3a CA,0 = 0.20 kg/m3 5.97 0.30 1.57 5.90 0.30
system 3b CA,0 = 0.25 kg/m3 5.93 0.30 1.58 6.11 0.31
system 3c CA,0 = 0.30 kg/m3 6.21 0.31 1.61 6.42 0.33
system 4a T = 303.15 K 334 15.2 70.3 389 17.7
system 4b T = 313.15 K 390 26.0 79.7 360 24.2
system 4c T = 323.15 K 440 46.3 104 363 38.3