Skip to main content
. 2021 Jun 10;38(7):1221–1234. doi: 10.1007/s11095-021-03069-x

Table II.

Size Distribution of the Naloxone-PLGA Microparticles Made with Different Formulations and Homogenization Conditions

Formulation Theoretical DL (%) L:G ratio Stator diameter (mm)-speed (RPM)-sieve size (μm) D10 (μm) D50 (μm) D90 (μm) Span
A50-L 30 50:50 10–5000–25 32.99 50.64 74.11 0.81
B50-L 40 50:50 10–5000–25 32.70 51.76 78.25 0.88
B50-S 40 50:50 25–3000–10 12.51 23.45 39.52 1.15
C50-L 50 50:50 10–5000–25 34.04 53.79 80.52 0.86
C50-S 50 50:50 25–3000–10 13.34 25.06 41.24 1.11
D50-L 60 50:50 10–5000–25 34.31 56.62 87.54 0.94
A75-L 30 75:25 10–5000–25 30.64 50.39 76.94 0.92
B75-L 40 75:25 10–5000–25 30.54 48.10 72.59 0.87
B75-S 40 75:25 25–3000–10 13.11 23.89 39.27 1.09
C75-L 50 75:25 10–5000–25 31.88 51.19 75.38 0.85
C75-S 50 75:25 25–3000–10 13.13 24.14 39.43 1.09
D75-L 60 75:25 10–5000–25 33.04 53.22 79.81 0.88